Front Panel Lock
The Front Panel Lock function is intended to minimize the probability of unintentional adjustments to the
system. Press MENU, select “Base Station Settings”, select “Front Panel Lock”, press 1 or ENTER to
select “Lock”. Press MENU to exit to the main Operational screen. The buttons and knobs on the front of
the base station will not function until unlocked, except the power switch will power the unit off. When the
base station is powered on it is always unlocked.
Press MENU + ENTER to unlock.
Call Function
On the base station front panel, select a channel by pressing the Volume control. Press and hold CALL
for as long as you want the Call signal to go out on the channel.
A Call signal will be received by users who are listening on the channel that originated the Call signal.
On the base station an active Talk button is not required to send a Call signal, and the Call signal is routed
to the channel selected for monitoring.
On the beltstation a Call signal is sent only when the Talk button is enabled, and only on the channel(s)
selected for Talk.