Clear-com Eclipse-PiCo Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 79
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
Clear-Com Communication Systems
Eclipse PiCo Matrix Instruction Manual
2-4
SETUP/ENTER KNOB
The setup/enter knob is used in conjunction with the display window
(see above) to perform a variety of actions directly from the PiCo
matrix, without any need for the Eclipse Configuration System
programming software. See the chapter “Using the PiCo’s Front Panel
Display Menus” in this manual for more information.
DEFAULT IP ADDRESS
From Eclipse 4.2 release onwards a factory default IP address
(172.16.2.100) is set up in the matrix firmware which will always be
available via an IP reset. This ensures that once the matrix firmware is
loaded it will always be possible to access the matrix via ethernet even
if the current IP address is not known.
To carry out an IP reset it is necessary to remove the cover of the
Eclipse PiCo in order to access the three reset switches positioned at
the front left of the main circuit board (viewed from the front of the unit)
shown in Figure 2-2. To carry out an IP reset press and hold the
rightmost two switches (nearest the side of the case) simultaneously
and then press and release the ‘RESET’ button at the front of the unit,
then release the internal switches. The unit will then be reset to the
factory default IP address.
The unit cover should be replace immediately the operation is
completed.
Warning: As the unit must be powered when resetting the IP
address this operation should only be carried out by
qualified service personnel.
Figure 2-2: Eclipse PiCo Reset Buttons
9
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 78 79

Commentaires sur ces manuels

Pas de commentaire