Appendix B:
Multiple Base Station Daisy-Chaining
Two or more DX210 base stations can be “daisy-chained” together with cables connected to the 2-W
connectors on the rear panels of each base station, following Clear-Com
®
/ RTS
®
standards, or two base
stations (not more) can be “daisy-chained” together with cables connected to the 4-W or AUX connectors.
NOTE 1: DX210 does not provide 2-wire line power, therefore, 2-wire power bypass must be used.
RTS
®
Mode Clear-Com
®
Mode
Pin 1 = Common
Pin 2 = Channel 1
Pin 3 = Channel 2
Pin 1 = Common
Pin 2 = N/C
Pin 3 = Audio
NOTE 2: For AUX type daisy-chaining, the cable connectors must be 3-pin XLR.
If using 4-wire connection, use cable with In/Out
crossed, as shown to the right.
(An Ethernet crossover cable will not work.)
IC In +  IC Out +
IC In –  IC Out –
IC Out +  IC In +
IC Out –  IC In –
If using 2-Wire connections, open each base station and set jumpers JP1 (IC1) and/or JP2 (IC2) in
all base stations to ON for power detect bypass. Set jumpers JP5 (IC1) and/or JP6 (IC2) in only one
base station per channel for termination. Refer to Appendix C, page 22.
Perform base station registration for each base station. Refer to Appendix D, page 23.